SunRising Precision [Yarn Guide-Nozzle] Engineering Department Comprehensive Test/Comparison Report
SunRising Precision [Yarn Guide] Nozzle Phase 1 Machine Test
Test Duration: 06/15 ~ 06/26, Total 11 Days
Yarn Type: 90/24 Nylon Black Yarn
Microscopic Surface Image of SunRising Nozzle Before Testing
Microscopic Surface Image of SunRising Nozzle After 11 Days of Testing
[SunRising Nozzle]
11-Day Test CV% = 0.41%
In-House Imported Nozzle
7-Day Test CV% = 0.43%
Elongation Variation During Use
Test Duration: 06/15 ~ 06/26, Total 11 Days, Average CV% = 1.95%
[SunRising Nozzle] Low Elongation Variation, Low Out-of-Spec Ratio
11-Day Test CV% = 1.95%
[In-House Imported Nozzle] 7-Day Test CV% = 2.18%
Uniformity Variation During Use
Test Duration: 06/15 ~ 06/26, Total 11 Days, Average CV% = 16.38%
[SunRising Nozzle] Stable Uniformity
11-Day Test CV% = 16.38%
[In-House Imported Nozzle] 7-Day Test CV% = 19.89%
Oil Content Variation During Use
Test Duration: 06/15 ~ 06/26, Total 11 Days, Average CV% = 2.23%
[SunRising Nozzle] Stable Oil Content
11-Day Test CV% = 2.23%
[In-House Imported Nozzle] 7-Day Test CV% = 7.36%
Phase 1 Test Summary
This test was conducted with the "90/24 Nylon Black Yarn" specification.
After 11 days of use, surface wear was minimal, indicating excellent wear resistance.
[SunRising Nozzle] outperformed imported nozzles in all physical property metrics, with significantly reduced yarn breakage.
[SunRising Nozzle] Within 7 Days, Yarn Breakage = 1.14 Times / 8 Spindles / Day (1 Break)
[SunRising Nozzle] Within 11 Days, Yarn Breakage = 1.45 Times / 8 Spindles / Day (2 Breaks)
[In-House Imported Nozzle] Within 7-Day Cycle, Yarn Breakage = 3.27 Times / 8 Spindles / Day
Yarn Breakage Comparison
Tension Variation Through Nozzle During Use
SunRising Precision [Yarn Guide-Nozzle] Engineering Department Comprehensive Test/Comparison Report 2
SunRising Precision [Yarn Guide] Nozzle Phase 2 Machine Test
Test Duration: Total 12 Days (Continued Use Without Replacement) Continuous UseTotal 23 Days
Yarn Type: Composite Yarn 125/32
Microscopic Surface Image of SunRising Nozzle Before Use
Microscopic Surface Image of SunRising Nozzle After 12 Days of Use
Uniformity Variation During Use
Trend charts show both nozzles generally fall within 0.80–1.20.
Over a 10-day nozzle usage cycle, in-house imported nozzles exhibit a higher out-of-spec ratio and greater variability in uniformity.
Thus, in terms of uniformity comparison, [SunRising Nozzle] outperforms in-house imported nozzles.
[SunRising Nozzle] Stable Uniformity
Oil Content Variation During Use
Although oil content showed minimal differences in tests at the same spindle, compared to other spindles of the same specification,
[SunRising Nozzle] demonstrates better oil content stability.
[SunRising Nozzle] Superior Oil Content Stability
Elongation Variation During Use
Under SunRising Nozzle testing, elongation mostly falls within standard values.
In-house imported nozzles show a higher out-of-spec ratio during use.
[SunRising Nozzle] Elongation Within Standard Values, Superior to In-House Imported Nozzles
Phase 2 Test Summary
SunRising Nozzle reached a cumulative usage of 23 days across the previous "90/24 Black Yarn" test and the current "125/32 Composite Yarn" test.
The nozzle surface shows no significant wear marks, indicating a high level of wear resistance.
Uniformity, oil content, and elongation comparisons clearly favor SunRising Nozzle over in-house imported nozzles, with stable tension and significantly reduced yarn breakage on average during testing.
Yarn Breakage Comparison
SunRising Precision [Yarn Guide-Nozzle] Engineering Department Comprehensive Test/Comparison Report 3
SunRising Precision [Yarn Guide] Nozzle Phase 3 Machine Test
Test Duration: Total 13 Days (Continued Use Without Replacement) Continuous UseTotal 36 Days
Yarn Type: 90/24 Nylon Black Yarn
Microscopic Surface Image of SunRising Nozzle After 36 Days, No Severe Wear Observed.